⚠️ IDLH ATMOSPHERE - IMMEDIATE DANGER ⚠️

HAZMATRIX PRO ONLINE

Field Decision Support
Confidence: low 0 inputs

Inputs

πŸ§ͺ Validation
Tap results you have. Unknown is fine.
Multi-gas meter
Life safety & atmosphere
LEL
%LEL (if available). Used for life-safety flags; Yes/None supports family filtering.
unknown
β€”
%LEL
Oxygen
Atmospheric Oβ‚‚ (%). Flagging displacement/enrichment.
β€”
%
Hβ‚‚S
Hydrogen sulfide (ppm). Exposure/tox hazard indicator.
β€”
ppm
CO
Carbon monoxide (ppm). Combustion / toxic indicator.
β€”
ppm
HCN
Hydrogen cyanide (ppm). Toxic gas channel (if equipped).
β€”
ppm
Chlorine
Clβ‚‚ (ppm). Toxic/irritant gas channel (if equipped).
β€”
ppm
Ammonia
NH₃ (ppm). IDLH: 300 ppm. PEL: 50 ppm.
β€”
ppm
Vapor characterization
PID / FID + supporting VOC
PID (VOC presence)
Photoionization response: ionizable VOCs present?
unknown
FID / Fuel Gas Response
Flame ionization / fuel indication: simple hydrocarbons present?
unknown
VOC Reading
PID concentration (ppm). Used as supporting evidence (not absolute).
β€”
ppm
Paper & Chemical Tests
Field test strips and reagent papers
🌫️
Wet pH Paper
For Vapors
unknown
πŸ’§
Dry pH Paper
For Wet Substances
unknown
βš—οΈ Fluorine (F)
unknown
πŸ›’οΈ Oil Test
unknown
πŸ“„ M8 Paper
unknown
πŸ’§ Beads: Rolls off β€” water-based / inorganic
πŸ“„ Absorbs: Organic liquid β€” alcohols, fuels, solvents absorb without color
⚠️ Absorbs + Color: Possible CWA β€” identify color below
πŸ§ͺ KI Paper
unknown
⚠️ Note: Activate paper with hydrochloric acid (HCl) before use
☣️ Chlorine Test
unknown
πŸ’¦ Water Finding Paper
unknown
Fire & Water Tests
Flame observation & solubility testing
πŸ”₯ Flame Observation
unknown
🌊 Solubility in Water
unknown
FTIR
Functional group indicators β€’ supporting evidence
FTIR Peaks (Tech Mode)
none
Tap peaks you see.
Radiation survey
Background compare β€’ abnormal detection
Background
β€”
Set your normal background for this instrument/location. Stored on this device.
Current Rate
β€”
Β΅Sv/h
Enter the current survey meter rate (same units as your background).
CPM
β€”
CPM
Counts per minute (if available). Informational only.
mR/hr
β€”
mR/hr
If your meter reports mR/hr, capture it here (no conversion applied).
Decontamination
Operational guidance β€’ not hazard ID
Decon Type
reference
Placeholder for gross / technical / emergency decon logic. This tab does NOT affect hazard scoring yet.
Water Reactivity
reference
Future hook for β€œdry decon vs water,” runoff control, etc.
⏳ Initializing weather data...
Engine: scoring + explainable output

HAZMAT SPECIALIST REPORT

πŸ“Š All Identification Possibilities

⚠️

IMPORTANT SAFETY NOTICE

Decision Support Tool - Always Verify Results

This application is a decision support tool only and should never be used as the sole basis for hazmat identification or tactical decisions.

Critical Requirements:

  • Confirm your findings - Use multiple detection methods, contact hazmat specialists, and reference technical resources
  • Check the ERG guidebook and cross-reference with placards, labels, and shipping papers
  • Follow your department SOPs and incident action plan at all times
  • Use your training and experience - this tool assists, but does not replace your judgment
  • Select PPE based on worst-case scenario, not solely on app suggestions

Known Limitations:

  • Field tests are presumptive only - different chemicals can give similar results
  • Accuracy depends on proper technique, clean equipment, and representative samples
  • Results show possibilities, not confirmed identification
  • Temperature, concentration, and chemical mixtures affect test results
⚠️ LIFE SAFETY WARNING: Wrong identification = wrong tactics = injuries or fatalities. Always use multiple methods to confirm the substance before committing personnel or resources.